Construction Grab Bar Wall Anchor for 3/4 - 1" Thick Partition Mounted Grab Bars with Snap-On Flange Covers shall be fabricated of alloy 18-8 stainless steel, type 304,
3" dia. plate 1/8" thick with two (2) 1/4-20 posts welded-on. Exposed side of plate shall have a No. 4 satin finish. Anchor kit shall
contain (1) Plate and (2) 1/4-20 x 3/4" long Phillips pan head machine screws. Specify one (1) kit per flange.
Installation Place grab bar on partition at desired location and mark mounting hole locations. Drill 3/8" (10mm) dia. holes through the partition at marked
locations. Place anchor at far side of partition and mount grab bar to it on near side with 1/4-20 machine screws (provided) to complete installation.
Refer to grab bar specification for correct procedure and strength data.
For compliance with ADA Accessibility Guidelines mount grab bar so that horizontal centerline is 33′′ (838mm) minimum to
36′′ (914mm) maximum above finished floor.